Fxs Loop Start Parameters - Multitech MultiVOIP MVP210 User Manual

Voice/fax over ip gateways
Hide thumbs Also See for MultiVOIP MVP210:
Table of Contents

Advertisement

FXS Loop Start Parameters

The parameters applicable to FXS Loop Start are shown in the figure below and described in the table
that follows.
Field Name
Dialing Options fields
FXS (Loop Start)
Inter Digit Timer
Message Waiting
Indication
Inter Digit
Regeneration Time
FXS Options fields
FXS Ring Count,
FXS
Current Loss
Generate Current
Reversal
Table is continued on next page...
Multi-Tech Systems, Inc.
Figure 4-4: FXS Loop Start parameters
FXS Loop Start Interface: Parameter Definitions
Values
Description
Y/N
Enables FXS Loop Start interface type.
1 - 10 seconds
This is the length of time that the MultiVOIP will wait between digits.
When the time expires, the MultiVOIP will look in the outbound
phonebook for the number entered and place the call accordingly.
Default = 2.
--
Not applicable to –SS series MultiVOIPs.
in milliseconds
The length of time between the outputting of DTMF digits.
Default = 100 ms.
1-10
Maximum number of rings that the MultiVOIP will issue before giving
up the attempted call.
Y/N
When enabled, the MultiVOIP will interrupt loop current in the FXS
circuit to initiate a disconnection. This tells the device connected to the
FXS port to hang up. The Multi-VOIP cannot drop the call; the FXS
device must go on hook.
Y/N
When selected, this option implements Answer Supervision and
Disconnect Supervision to the FXO interface using current reversal to
indicate events. Applicable only when FXS and FXO interfaces are
connected back to back.