Multitech MultiVOIP MVP210 User Manual page 101

Voice/fax over ip gateways
Hide thumbs Also See for MultiVOIP MVP210:
Table of Contents

Advertisement

Call is received
here.
Terminating
FXS
xxxyyyzzzz
J.Q. Public
11/15, 6:17pm
Display shows:
CID Number: 423
CID Name:
Anoka-Whse-VP3
Time Stamp: Date: 11/15
Time: 6:17pm
*
In x.06 release, when SIP protocol is used,
CID Name field will duplicate value in
CID Number field.
Figure 5-29: VOIP Caller ID Case #5 – Call through telco central office without standard CID enters DID channel
in H.323 VOIP system.
Multi-Tech Systems, Inc.
CID Flow
CID
VoIP
IP
Network
Clock:
*
H.323 Protocol
Figure 5-28: Caller ID example 5
CID
Ch1
Generating
Central Office
DID
VoIP
without
Ch2
standard telephony
Caller ID service
Ch3
Ch4
Phone Book Configuration
Gateway Name: Anoka-Whse-VP3
Q.931 Parameters
Inbound Phone Book
Remove Prefix
Gatekeeper RAS Parameters
Chapter 5: Phonebook Configuration
Call originates here
at 6:17pm, Nov 15.
xxxyyyzzzz
J.Q. Public
phone of:
Edwin Smith
763-743-5873
{Channel 2}
Add Prefix
Forward/Addr
423
748
101