Configuration and Use Manual
MMI-20016855
3 Introduction to configuration and
commissioning
3.1 Configuration flowchart
Use the following flowchart as a general guide to the configuration and commissioning process.
Some options may not apply to your installation. Detailed information is provided in the remainder of this
manual.
Configure process measurement
Configure mass flow
measurement
Configure volume flow
meaurement
Volume flow type
Liquid
Configure flow direction
Configure density
measurement
Configure temperature
measurement
Configure petroleum
measurement (API)
application (if available)
Configure concentration
measurement application
(if available)
Configure pressure
compensation (optional)
Configuration and Use Manual
Configure device options and
preferences
Gas
Define gas properties
Integrate device with control system
Introduction to configuration and commissioning
Test and move to production
Configure display
parameters
Configure fault handling
parameters
Configure sensor
parameters
Configure device
parameters
Configure the mA
output(s)
Configure the frequency
output(s)
Configure the discrete
output(s)
Configure the discrete
input
Configure the mA input
Configure events
Configure digital
communications
June 2019
Test or tune transmitter
using sensor simulation
Back up transmitter
configuration
Enable write-protection on
transmitter configuration
Done
17