EtherNet/IP
6.4 Supported CIP objects for EtherNet/IP
Attribute
Access
Designation
ID
rule
Forced inter-
face speed
7
Retrieve
Interface type
8
Retrieve
Interface sta-
tus
10
Retrieve
Interface name Human-readable identifier
11
Retrieve
Interface ca-
pability
Function bits
Speed/duplex
options
96
Description
Speed at which the interface is
supposed to work
Interface type: Twisted pair,
fiber, internal, etc.
Current status of the interface:
in operation, disabled, etc.
Shows the capabilities of the
interface
Interface capabilities except
speed/duplex
Shows speed/duplex pairs sup-
ported by the interface control
attribute
Speed/duplex array counter
Speed/duplex array
Interface speed
Interface duplex mode
Hardware Installation and Operating Manual, 07/2020, A5E50018670-AA
Data type
Value semantics
UINT
Speed in Mbps (10, 100, etc.).
When the autonegotiation bit is
0, the forced interface speed bits
show the speed at which the
interface is to operate.
USINT
2 = Twisted pair
3 = Optical fiber
USINT
0 = Unknown
1 = Enabled and ready for send-
ing (default)
2 = Disabled
3 = Testing
SHORT_STRI
"Siemens, SIMATIC S7, Ethernet
NG
Port, X1 P1 R"
"Siemens, SIMATIC S7, Ethernet
Port, X1 P2 R"
STRUCT
----
from:
DWORD
Bitmap
STRUCT
----
from:
USINT
Number of elements
ARRAY of
----
STRUCT
from:
USINT
The semantics are the same as
for the forced interface speed in
the interface control attribute:
Speed in Mbps.
USINT
0 = Half-duplex
1 = Full duplex
2 to 255 = Reserved