Output buffer
The following table shows the output buffer for the example configuration for the I/O data
alignment Word:
Slot
Name*
1
Slot1_1_Id_0_Outputs
Slot1_1_Id_1_Outputs
3
Slot3_1_Id_0_Outputs
Slot3_1_Id_1_Outputs
4
Slot4_1_Id_0_Outputs
Slot4_1_Id_1_Padding
6
Slot6_1_Id_0_Outputs
Slot6_1_Id_1_Outputs
Slot6_1_Id_2_Outputs
Slot6_1_Id_3_Outputs
Slot6_1_Id_4_Outputs
Slot6_1_Id_5_Outputs
Slot6_1_Id_6_Outputs
Slot6_1_Id_7_Outputs
Slot6_1_Id_8_Outputs
Slot6_1_Id_9_Outputs
Slot6_1_Id_10_Outputs
Slot6_1_Id_11_Outputs
* The name is formed according to the following scheme: Slot<Slot#>_<Subslot#>_Id_<Id#>_<DataItem-TextId>
The sum of the output data is 18 bytes.
PN/MF Coupler
Hardware Installation and Operating Manual, 07/2020, A5E50018670-AA
Data
Byte
Description
type
offset
Byte
0
OUT 2 Byte
Byte
1
Byte
2
OUT 2 Byte
Byte
3
Byte
4
OUT 1 Byte
Byte
5
Padding byte
Byte
6
PROFIsafe IN/OUT 6 Byte / 12 Byte
Byte
7
Byte
8
Byte
9
Byte
10
Byte
11
Byte
12
Byte
13
Byte
14
Byte
15
Byte
16
Byte
17
6.2 Integration into the automation system