Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC BusAdapter

  • Page 2 Preface Guide SIMATIC Product overview BusAdapter BA 2xRJ45 ET 200SP BusAdapter BusAdapter BA 2xFC BusAdapter BA 2xSCRJ Equipment Manual BusAdapter BA 2xLC BusAdapter BA 2xM12 BusAdapter BA SCRJ/RJ45 BusAdapter BA SCRJ/FC BusAdapter BA LC/RJ45 BusAdapter BA LC/FC Strain relief Dimension drawings Accessories Compatibility 08/2020...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Table of contents Preface ..............................5 Security information ......................6 Siemens Industry Online Support ..................6 Industry Mall........................7 Guide ..............................8 Product overview ..........................11 BusAdapter BA 2xRJ45 ......................... 14 Product overview ....................... 14 Connecting ........................15 Diagnostics ........................18 Technical specifications .....................
  • Page 5 Table of contents BusAdapter BA SCRJ/RJ45 ........................49 Product overview ....................... 49 Connecting ........................50 Diagnostics ........................52 Technical specifications ..................... 54 BusAdapter BA SCRJ/FC ........................55 10.1 Product overview ....................... 55 10.2 Connecting ........................56 10.3 Diagnostics ........................58 10.4 Technical specifications .....................
  • Page 6: Preface

    Purpose of the documentation This manual supplements the system manual ET 200SP distributed I/O system (https://support.automation.siemens.com/WW/view/en/58649293). Functions that generally relate to the system are described in this manual. The information provided in this manual and in the system/function manuals supports you in commissioning the system.
  • Page 7: Security Information

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 8: Industry Mall

    Preface 1.3 Industry Mall Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP). You can find catalogs for all automation and drive products on the Internet (https://mall.industry.siemens.com).
  • Page 9: Guide

    You must register once to use the full functionality of "mySupport". You can find "mySupport" on the Internet (https://support.industry.siemens.com/My/ww/de/). "mySupport" - Documentation In the Documentation area of "mySupport", you have the possibility to combine complete manuals or parts of them to make your own manual.
  • Page 10 • Manuals, characteristics, operating manuals, certificates • Product master data You can find "mySupport" - CAx data on the Internet (http://support.industry.siemens.com/my/ww/de/CAxOnline). Application examples The application examples support you with various tools and examples for solving your automation tasks. Solutions are shown in interplay with multiple components in the system - separated from the focus on individual products.
  • Page 11 Guide PRONETA With SIEMENS PRONETA (PROFINET network analysis), you analyze the plant network during commissioning. PRONETA features two core functions: • The topology overview independently scans PROFINET and all connected components. • PRONETA also scans: configuration of the station name, IP subnet mask and identification and maintenance data (I&M1..3)
  • Page 12: Product Overview

    SIMATIC BusAdapter. Supported PROFINET devices The SIMATIC BusAdapter can be used, for example, for: • ET 200SP interface module and central processing unit (CPU and Open Controller) • PN/PN Coupler •...
  • Page 13 Product overview BusAdapter Article number Property Figure BA 2xSCRJ 6ES7193-6AP00-0AA0 PROFINET BusAdapter with fiber-optic cable connection POF/PCF for SCRJ connector for applications with increased EMC and vibration/shock load as well as electrical potential differ- ences between two stations BA 2xLC 6ES7193-6AG00-0AA0 PROFINET BusAdapter with glass fiber-optic cable connec-...
  • Page 14 Product overview BusAdapter Article number Property Figure BA SCRJ/FC 6ES7 193-6AP40-0AA0 Media converter, PROFINET BusAdapter with POF/PCF fiber- optic cable ⇔ direct connection of bus cable BA LC/RJ45 6ES7193-6AG20-0AA0 Media converter, PROFINET BusAdapter with glass fiber- optic cable ⇔ standard RJ45 connector BA LC/FC 6ES7193-6AG40-0AA0...
  • Page 15: Busadapter Ba 2Xrj45

    BusAdapter BA 2xRJ45 Product overview Article number 6ES7193-6AR00-0AA0 View Figure 4-1 BusAdapter BA 2×RJ45 Properties • You connect PROFINET IO cable with RJ45 connector to the PROFINET device via the BusAdapter BA 2×RJ45. To do this, screw the BusAdapter BA 2×RJ45 to the PROFINET device and insert the PROFINET connecting cable.
  • Page 16: Connecting

    BusAdapter BA 2xRJ45 4.2 Connecting Connecting Installing the bus connector Install the PROFINET connector according to the instructions in the PROFINET Installation Guide (https://www.profibus.com/). Tools required 3 to 3.5 mm screwdriver, alternatively TX10 (torx). Accessories required • Connector: – IE FC RJ45 plug 180 2X2 (6GK1901-1BB10-2A) –...
  • Page 17 4.2 Connecting Procedure Watch video sequence "Connect BusAdapter BA 2xRJ45 to the ET 200SP interface module" (https://support.industry.siemens.com/cs/ww/de/view/95886218) To connect PROFINET IO to the PROFINET device via the BusAdapter BA 2xRJ45, follow these steps: 1. Plug the BusAdapter BA 2×RJ45 into the PROFINET device.
  • Page 18 BusAdapter BA 2xRJ45 4.2 Connecting Note Installation guidelines for modules with PROFINET IO interfaces Ensure that all devices are connected to the SELV/PELV power supply (or equivalent). Only then are you permitted to operate the modules with PROFINET IO interfaces in LAN networks (Local Area Networks).
  • Page 19: Diagnostics

    BusAdapter BA 2xRJ45 4.3 Diagnostics Diagnostics LEDs The figure below shows the LEDs on the BusAdapter BA 2xRJ45: ① LK1 (green) ② LK2 (green) Figure 4-3 LEDs on the BusAdapter BA 2xRJ45 LK1/LK2 LEDs on the BusAdapter Table 4- 2 Status and error displays Meaning Remedy...
  • Page 20: Technical Specifications

    Technical specifications Technical specifications of BusAdapter BA 2×RJ45 The following table shows the technical specifications as of 02/2020. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/de/en/pv/6ES7193-6AR00-0AA0/td?dl=de). Article number 6ES7193-6AR00-0AA0 General information Product type designation...
  • Page 21: Busadapter Ba 2Xfc

    BusAdapter BA 2xFC Product overview Article number 6ES7193-6AF00-0AA0 View Figure 5-1 BusAdapter BA 2xFC Properties • You connect PROFINET IO cable with FastConnect connection method to the PROFINET device via the BusAdapter BA 2xFC. To do this, screw the BusAdapter BA 2xFC with the connected PROFINET connection cable in place on the PROFINET device.
  • Page 22: Connecting

    BusAdapter BA 2xFC 5.2 Connecting Connecting Installing the bus connector Install the PROFINET connector according to the instructions in the PROFINET Installation Guide (https://www.profibus.com/). Tools required 3 to 3.5 mm screwdriver, alternatively TX10 (torx). Accessories required • If you use Fast Connect Cable, we recommend the Industrial Ethernet Fast Connect Stripping Tool (6GK1901-1GA00) with green knife cassette (6GK1901-1B).
  • Page 23 Transmit Data + Procedure Watch the video sequence "Connecting the BusAdapter BA 2xFC to the interface module" (https://support.industry.siemens.com/cs/ww/de/view/95886218) To connect PROFINET IO to the PROFINET device via the BusAdapter BA 2xFC, follow these steps: 1. Strip insulation from the sheath of the PROFINET connecting cable as follows:...
  • Page 24 BusAdapter BA 2xFC 5.2 Connecting 5. Close the cover of the connection element. Then push the locking slide forwards as far as it will go. 6. Screw the BusAdapter BA 2×FC to the PROFINET device (1 screw with 0.25 Nm tightening torque).
  • Page 25 BusAdapter BA 2xFC 5.2 Connecting BusAdapter BA 2xFC installed ① ② BusAdapter BA 2xFC ③ PROFINET connecting cable ④ Connection element Figure 5-4 BusAdapter BA 2xFC installed (using an ET 200SP CPU/interface module as an example) Note Installation guidelines for modules with PROFINET IO interfaces Ensure that all devices are connected to the SELV/PELV power supply (or equivalent).
  • Page 26: Diagnostics

    BusAdapter BA 2xFC 5.3 Diagnostics Diagnostics LEDs The figure below shows the LEDs on the BusAdapter BA 2xFC: ① LK1 (green) ② LK2 (green) Figure 5-5 LEDs on the BusAdapter BA 2xFC LK1/LK2 LEDs on the BusAdapter Table 5- 2 Status and error displays Meaning Remedy...
  • Page 27: Technical Specifications

    2 000 m; On request: Installation altitudes greater • Installation altitude above sea level, max. than 2 000 m Dimensions Width 20 mm Height 69.5 mm Depth 59 mm Weights Weight, approx. 53 g See also Technical specifications SIOS (https://support.industry.siemens.com/cs/de/en/pv/6ES7193- 6AF00-0AA0/td?dl=de) BusAdapter Equipment Manual, 08/2020, A5E41449003-AB...
  • Page 28: Busadapter Ba 2Xscrj

    BusAdapter BA 2xSCRJ Product overview Article number 6ES7193-6AP00-0AA0 View Figure 6-1 BusAdapter BA 2xSCRJ Properties • Using BusAdapter BA 2×SCRJ , you connect PROFINET IO to the PROFINET device optically with fiber-optic cables via an SCRJ connector. To do this, screw the BusAdapter BA 2×SCRJ to the PROFINET device and plug in the SCRJ connector.
  • Page 29: Connecting

    BusAdapter BA 2xSCRJ 6.2 Connecting Connecting Installing the bus connector Install the PROFINET connector according to the instructions in the PROFINET Installation Guide (https://www.profibus.com/). Tools required 3 to 3.5 mm screwdriver, alternatively TX10 (torx). Accessories required • Connector for PROFINET connection: IE SCRJ POF Plug •...
  • Page 30 BusAdapter BA 2xSCRJ 6.2 Connecting Pin assignment The following table shows the signal name and description of the pin assignment of the BusAdapter BA 2×SCRJ. Table 6- 1 PROFINET IO pin assignment with BusAdapter BA 2×SCRJ View Signal name Description ①...
  • Page 31 This will prevent any attenuation losses caused by re-bent, heavily stressed portions of the fiber-optic cores. Reference For more information on the installation guidelines for fiber-optic cables, refer to the SIMATIC NET PROFIBUS Network Manual (https://support.industry.siemens.com/cs/de/de/view/1172302). BusAdapter Equipment Manual, 08/2020, A5E41449003-AB...
  • Page 32: Diagnostics

    BusAdapter BA 2xSCRJ 6.3 Diagnostics Diagnostics LEDs The figure below shows the LED display on the BusAdapter BA 2xSCRJ: ① LK1 (green) ② MT1 (yellow) ③ LK2 (green) ④ MT2 (yellow) Figure 6-3 LEDs on the BusAdapter BA 2xSCRJ BusAdapter Equipment Manual, 08/2020, A5E41449003-AB...
  • Page 33 BusAdapter BA 2xSCRJ 6.3 Diagnostics LK1/LK2 and MT1/MT2 LEDs on the BusAdapter Table 6- 2 Status and error displays Meaning Remedy LK1/LK2 MT1/MT2 Not relevant There is no Ethernet connection be- Check whether the bus cable to the switch or tween the PROFINET IO interface of IO controller is disconnected.
  • Page 34: Technical Specifications

    Technical specifications Technical specifications of BusAdapter BA 2×SCRJ The following table shows the technical specifications as of 02/2020. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/de/en/pv/6ES7193-6AP00-0AA0/td?dl=de). Article number 6ES7193-6AP00-0AA0 General information Product type designation...
  • Page 35: Busadapter Ba 2Xlc

    BusAdapter BA 2xLC Product overview Article number 6ES7193-6AG00-0AA0 View Figure 7-1 BusAdapter BA 2xLC Properties • You connect PROFINET IO fiber-optic cables to the PROFINET device via the BusAdapter BA 2×LC. To do this, screw the BusAdapter BA 2×LC to the PROFINET device and insert the PROFINET connection cable.
  • Page 36: Connecting

    BusAdapter BA 2xLC 7.2 Connecting Connecting Installing the bus connector Install the PROFINET connector in accordance with the instructions in the PROFINET Installation Guide (https://www.profibus.com/). Tools required 3 to 3.5 mm screwdriver, alternatively TX10 (torx). Accessories required • If you prepare the FC FO cables with the IE FC FO LC plug, we recommend the FC FO Termination Kit (LC) (6GK1900-0RL00-0AA0).
  • Page 37 BusAdapter BA 2xLC 7.2 Connecting Pin assignment The following table shows the signal name and description of the pin assignment of the BusAdapter BA 2×LC: Table 7- 1 PROFINET IO pin assignment with BusAdapter BA 2xLC View Signal name Description ①...
  • Page 38 BusAdapter BA 2xLC 7.2 Connecting Procedure To connect PROFINET IO to the PROFINET device via the BusAdapter BA 2xLC, follow these steps: 1. Plug the BusAdapter BA 2xLC into the PROFINET device. 2. Screw the BusAdapter BA 2xLC to the PROFINET device (1 screw with 0.25 Nm tightening torque).
  • Page 39 This will prevent any attenuation losses caused by re-bent, heavily stressed portions of the fiber-optic cores. Reference For more information on the installation guidelines for fiber-optic cables, refer to the SIMATIC NET PROFIBUS Network Manual (https://support.industry.siemens.com/cs/de/de/view/1172302). BusAdapter Equipment Manual, 08/2020, A5E41449003-AB...
  • Page 40: Diagnostics

    BusAdapter BA 2xLC 7.3 Diagnostics Diagnostics LEDs The figure below shows the LEDs on the BusAdapter BA 2xLC: ① LK1 (green) ② LK2 (green) Figure 7-3 LEDs on the BusAdapter BA 2xLC LK1/LK2 LEDs on the BusAdapter Table 7- 2 Status and error displays Meaning Remedy...
  • Page 41: Technical Specifications

    Technical specifications Technical specifications of BusAdapter BA 2xLC The following table shows the technical specifications as of 02/2020. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/de/en/pv/6ES7193-6AG00-0AA0/td?dl=de). Article number 6ES7193-6AG00-0AA0 General information Product type designation...
  • Page 42: Busadapter Ba 2Xm12

    BusAdapter BA 2xM12 Product overview Article number 6ES7193-6AM00-0AA0 View Figure 8-1 View BA 2xM12 Properties • Two M12 push-pull sockets according to IEC 61076-2-012 • Connection option of the PROFINET line using two connector versions: – Pluggable push-pull version (see the section "Accessories required") –...
  • Page 43: Connecting

    BusAdapter BA 2xM12 8.2 Connecting Connecting Installing the bus connector Fit the PROFINET connector according to the instructions in downloads, PROFINET Installation Guide (https://www.profibus.com/). Note Push-pull connector For simplifying installation (only plugging in instead of screwing with a defined torque), we recommend using the push-pull plug for the PROFINET connection.
  • Page 44 BusAdapter BA 2xM12 8.2 Connecting • Siemens pre-assembled connector/cable M12 D-coded without push/pull up to a maximum length of 15 m: – IE Connecting Cable M12-180/M12-180 0.3M (6XV1870-8A E30) – IE Connecting Cable M12-180/M12-180 0.5M (6XV1870-8A E50) – IE Connecting Cable M12-180/M12-180 1M (6XV1870-8A H10) –...
  • Page 45 BusAdapter BA 2xM12 8.2 Connecting Procedure for standard M12 connector To connect PROFINET IO to the PROFINET device via the BusAdapter BA 2xM12, follow these steps: 1. Plug the BusAdapter BA 2×M12 into the PROFINET device. 2. Screw the BusAdapter BA 2×M12 to the PROFINET device (1 screw with 0.25 Nm tightening torque).
  • Page 46 BusAdapter BA 2xM12 8.2 Connecting BusAdapter BA 2xM12 installed ① Interface module ② BusAdapter BA 2xM12 ③ PROFINET connecting cable with M12 connector Figure 8-2 Connect the BusAdapter BA 2xM12 to the interface module Note Installation guidelines for modules with PROFINET IO interfaces Ensure that all devices are connected to the SELV/PELV power supply (or equivalent).
  • Page 47 BusAdapter BA 2xM12 8.2 Connecting Using accessories • Use the strain relief (Page 71) for vibration loads exceeding 1g. • For easier removal of push-pull connectors, fit the unlatching straps, 6ES7193-6DL00- 2AA0 (under development). ① Unlatching straps ② Strain relief Figure 8-3 Using accessories Compatibility of the M12 sockets used...
  • Page 48: Diagnostics

    BusAdapter BA 2xM12 8.3 Diagnostics Diagnostics LED displays The figure below shows the LEDs on the BusAdapter BA 2xM12: ① LK1 (green) ② LK2 (green) Figure 8-4 LEDs on the BusAdapter BA 2xM12 LK1/LK2 LEDs on the BusAdapter Table 8- 2 Status and error displays Meaning Remedy...
  • Page 49: Technical Specifications

    Internet (https://support.industry.siemens.com/cs/de/en/pv/6ES7193-6AM00-0AA0/td?dl=de). Article number 6ES7193-6AM00-0AA0 General information Product type designation SIMATIC BusAdapter BA 2x M12 Interfaces Number of PROFINET interfaces Supports protocol for PROFINET IO • Number of M12 ports Cable length...
  • Page 50: Busadapter Ba Scrj/Rj45

    BusAdapter BA SCRJ/RJ45 Product overview Article number 6ES7193-6AP20-0AA0 View ① Fiber-optic cable SCRJ ② RJ45 Figure 9-1 BusAdapter BA SCRJ/RJ45 Properties You connect PROFINET IO connection cables to the PROFINET device via the BusAdapter BA SCRJ/RJ45: • Optically with fiber-optic cables (FOC) with an SCRJ connector to port 1 •...
  • Page 51: Connecting

    BusAdapter BA SCRJ/RJ45 9.2 Connecting Connecting Installing the bus connector Install the PROFINET connector in accordance with the instructions in the PROFINET Installation Guide (https://www.profibus.com/). Connecting the SCRJ connector You can find more information about the required tools, accessories, requirements and procedures in the section Connecting BusAdapter BA 2×SCRJ (Page 28).
  • Page 52 BusAdapter BA SCRJ/RJ45 9.2 Connecting BA SCRJ/RJ45 BusAdapter mounted ① Interface module ② BusAdapter BA SCRJ/RJ45 ③ PROFINET connecting cable Figure 9-2 Connecting the BusAdapter BA SCRJ/RJ45 to the interface module Note Installation guidelines for modules with PROFINET IO interfaces Ensure that all devices are connected to the SELV/PELV power supply (or equivalent).
  • Page 53: Diagnostics

    BusAdapter BA SCRJ/RJ45 9.3 Diagnostics Diagnostics LEDs The figure below shows the LEDs on the BusAdapter BA SCRJ/RJ45: ① LK1 (green) ② MT (yellow) ③ LK2 (green) Figure 9-3 LED displays on the BusAdapter BA SCRJ/RJ45 LK1/LK2 and MT LEDs on the BusAdapter Table 9- 2 Status and error displays Meaning...
  • Page 54 BusAdapter BA SCRJ/RJ45 9.3 Diagnostics Meaning Remedy LK1/LK2 Not relevant No error Not relevant Causes and measures for the transmission • Fiber-optic error route: • Maintenance demanded: attenua- • Replace the fiber-optic cable if damaged tion through the fiber-optic cable or aged.
  • Page 55: Technical Specifications

    Technical specifications Technical specifications of BusAdapter BA SCRJ/RJ45 The following table shows the technical specifications as of 02/2020. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/de/en/pv/6ES7193-6AP20-0AA0/td?dl=de). Article number 6ES7193-6AP20-0AA0 General information Product type designation...
  • Page 56: Busadapter Ba Scrj/Fc

    BusAdapter BA SCRJ/FC 10.1 Product overview Article number 6ES7193-6AP40-0AA0 View ① SCRJ fiber-optic cable ② FastConnect FC Figure 10-1 BusAdapter BA SCRJ/FC Properties • You connect PROFINET IO to the PROFINET device via the BusAdapter BA SCRJ/FC . • The BusAdapter BA SCRJ/FC has one port for connection of a copper cable and one port for connection of a fiber-optic cable.
  • Page 57: Connecting

    BusAdapter BA SCRJ/FC 10.2 Connecting 10.2 Connecting Installing the bus connector Install the PROFINET connector according to the instructions in the PROFINET Installation Guide (https://www.profibus.com/). Connecting the SCRJ connector You can find more information about the required tools, accessories, requirements and procedures in the section Connecting BusAdapter BA 2×SCRJ (Page 28).
  • Page 58 BusAdapter BA SCRJ/FC 10.2 Connecting BusAdapter BA SCRJ/FC installed ① Interface module ② BusAdapter BA SCRJ/FC ③ PROFINET connecting cable Figure 10-2 BusAdapter BA SCRJ/FC installed (using an ET 200SP interface module as an example) Note Installation guidelines for modules with PROFINET IO interfaces Ensure that all devices are connected to the SELV/PELV power supply (or equivalent).
  • Page 59: Diagnostics

    BusAdapter BA SCRJ/FC 10.3 Diagnostics 10.3 Diagnostics LEDs The figure below shows the LEDs on the BusAdapter BA SCRJ/FC: ① LK1 (green) ② MT (yellow) ③ LK2 (green) Figure 10-3 LEDs on the BusAdapter BA SCRJ/FC BusAdapter Equipment Manual, 08/2020, A5E41449003-AB...
  • Page 60 BusAdapter BA SCRJ/FC 10.3 Diagnostics LK1/LK2 and MT LEDs on the BusAdapter Table 10- 2 Status and error displays Meaning Remedy LK1/LK2 Not relevant There is no Ethernet connec- Check whether the bus cable to the tion between the PROFINET IO switch or IO controller is disconnect- interface of your PROFINET device and a communication...
  • Page 61: Technical Specifications

    Technical specifications Technical specifications of BusAdapter BA SCRJ/FC The following table shows the technical specifications as of 02/2020. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/de/en/pv/6ES7193-6AP40-0AA0/td?dl=de). Article number 6ES7193-6AP40-0AA0 General information Product type designation...
  • Page 62: Busadapter Ba Lc/Rj45

    BusAdapter BA LC/RJ45 11.1 Product overview Article number 6ES7193-6AG20-0AA0 View ① Glass fiber-optic cable LC ② RJ45 Figure 11-1 BusAdapter BA LC/RJ45 Properties You connect PROFINET IO connection cables to the PROFINET device via the BusAdapter BA LC/RJ45: • Optically with glass fiber-optic cables with an LC connector to port 1 •...
  • Page 63: Connecting

    BusAdapter BA LC/RJ45 11.2 Connecting 11.2 Connecting Installing the bus connector Install the PROFINET connector in accordance with the instructions in the PROFINET Installation Guide (https://www.profibus.com/). Attaching LC connectors You can find more information about the required tools, accessories, requirements and procedures in the section Connecting BusAdapter BA 2×LC (Page 35).
  • Page 64 BusAdapter BA LC/RJ45 11.2 Connecting BusAdapter BA LC/RJ45 installed ① Interface module ② BusAdapter BA LC/RJ45 ③ PROFINET connecting cable Figure 11-2 BusAdapter BA LC/RJ45 installed (using an ET 200SP interface module as an example) Note Installation guidelines for modules with PROFINET IO interfaces Ensure that all devices are connected to the SELV/PELV power supply (or equivalent).
  • Page 65: Diagnostics

    BusAdapter BA LC/RJ45 11.3 Diagnostics 11.3 Diagnostics LEDs The figure below shows the LEDs on the BusAdapter BA LC/RJ45: ① LK1 (green) ② LK2 (green) Figure 11-3 LED displays on the BusAdapter BA LC/RJ45 LEDs LK1/LK2 on the BusAdapter Table 11- 2 Status and error displays Meaning Remedy...
  • Page 66: Technical Specifications

    Technical specifications Technical specifications of the BusAdapters BA LC/RJ45 The following table shows the technical specifications as of 02/2020. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/de/en/pv/6ES7193-6AG20-0AA0/td?dl=de). Article number 6ES7193-6AG20-0AA0 General information Product type designation...
  • Page 67: Busadapter Ba Lc/Fc

    BusAdapter BA LC/FC 12.1 Product overview Article number 6ES7193-6AG40-0AA0 View ① Glass fiber-optic cable LC ② FastConnect FC Figure 12-1 BusAdapter BA LC/FC Properties You connect PROFINET IO connection cables to the PROFINET device via the BusAdapter BA LC/FC: • Optically with glass fiber-optic cables with an LC connector to port 1 •...
  • Page 68: Connecting

    BusAdapter BA LC/FC 12.2 Connecting 12.2 Connecting Installing the bus connector Install the PROFINET connector in accordance with the instructions in the PROFINET Installation Guide (https://www.profibus.com/). Attaching LC connectors You can find more information about the required tools, accessories, requirements and procedures in the section Connecting BusAdapter BA 2×LC (Page 35).
  • Page 69 BusAdapter BA LC/FC 12.2 Connecting BusAdapter BA LC/FC installed ① Interface module ② BusAdapter BA LC/FC ③ PROFINET connecting cable Figure 12-2 Connecting the BusAdapter BA LC/FC to the interface module Note Installation guidelines for modules with PROFINET IO interfaces Ensure that all devices are connected to the SELV/PELV power supply (or equivalent).
  • Page 70: Diagnostics

    BusAdapter BA LC/FC 12.3 Diagnostics 12.3 Diagnostics LEDs The figure below shows the LEDs on the BusAdapter BA LC/FC: ① LK1 (green) ② LK2 (green) Figure 12-3 LEDs on the BusAdapter BA LC/FC LK1/LK2 LEDs on the BusAdapter Table 12- 2 Status and error displays Meaning Remedy...
  • Page 71: Technical Specifications

    Technical specifications Technical specifications of the BusAdapters BA LC/FC The following table shows the technical specifications as of 02/2020. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/de/en/pv/6ES7193-6AG40-0AA0/td?dl=de). Article number 6ES7193-6AG40-0AA0 General information Product type designation...
  • Page 72: Strain Relief

    Strain relief 13.1 Product overview Article number 6ES7193-6RA00-1AN0 (VPE: 5 strain relief units incl. screws) View Figure 13-1 Strain relief Properties • The strain relief is a mechanical protective device for the electrical PROFINET cables on the BusAdapter. • The strain relief is suitable for all optical and electrical PROFINET cables of the BusAdapter. •...
  • Page 73: Installing

    Strain relief 13.2 Installing 13.2 Installing Requirement • The PROFINET cables are not inserted on the BusAdapter. The inserted PROFINET cables hamper the mounting of the strain relief. • BusAdapter and strain relief can be mounted separately. Tools required Screwdriver TX10 (torx). Procedure To install the strain relief, follow these steps: 1.
  • Page 74 Strain relief 13.2 Installing 4. Screw the BusAdapter to the PROFINET device (1 screw with 0.25 Nm tightening torque). 5. Fasten each PROFINET cable individually to the strain relief with the cable ties. Figure 13-3 Strain relief installed BusAdapter Equipment Manual, 08/2020, A5E41449003-AB...
  • Page 75: Dimension Drawings

    Dimension drawings BusAdapter dimension drawings The figure below shows the dimension drawing of the BusAdapter BA 2xRJ45 as an example. Figure A-1 Dimensional drawing of BusAdapter BA 2xRJ45 Strain relief dimension drawings The figure below shows the dimension drawing of the strain relief. Figure A-2 Strain relief dimension drawing BusAdapter...
  • Page 76: Accessories

    Accessories Accessories Additional accessories are available for the SIMATIC BusAdapters: Accessories Article number Property Figure Strain relief 6ES7193-6RA00- The strain relief is a mechanical 1AN0 protective device for the electrical PROFINET cables on the BusAdapt- er. The strain relief can be ordered as optional accessories.
  • Page 77: Compatibility

    Compatibility Overview of the introduction of the BusAdapter in the engineering tools The table shows with which STEP 7 version or HSP version you can use the BusAdapters. STEP 7 Classic STEP 7 TIA Portal In STEP 7 Release HSP version available from installable from BA 2xRJ45...

Table of Contents