Mitsubishi Electric MELDAS C6 Programming Manual page 324

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

15. Measurement Support Functions
Detailed description
(1) The skip is specified by command speed f. Note that the F modal is not updated.
(2) The skip signal is specified by skip signal parameter p. p can range from 1 to 15. If p is
specified outside the range, program error (P35) occurs.
Skip signal
command
(Skip when " " signal is input.)
(3)
The specified skip signal command is a logical sum of the skip signals.
(Example)
P
4
1
×
2
×
3
×
4
×
5
×
6
×
7
×
8
9
10
11
12
13
14
15
G31 X100. P5 F100 ;
316
15.4
Multi-step skip function 2
Valid skip signal
3
2
1
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Operation is skipped if skip signal 1 or 3 is input.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents