Mitsubishi Electric MELDAS C6 Programming Manual page 223

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

13. Program Support Functions
(d) Registration No.
(e) Data type
Variable No.
Item
60001
Number of
registered tools
60002
Life current value
60003
Tool selected No.
60004
Number of
remaining
registered tools
60005
Signal being
executed
60006
Cutting time
cumulative value
(minute)
60007
Life end signal
60008
Life prediction
signal
M System
1 to 200
L System
1 to 16
Type
M System
Number of
1
registered tools
2
Life current value
3
Tool selected No.
Number of
4
remaining
registered tools
Signal being
5
executed
Cutting time
6
cumulative value
(minute)
7
Life end signal
Life prediction
8
signal
Type
Common to
Total number of tools registered in each group.
system
For each group
Usage time/No. of uses of tool being used.
(Designate
Spindle tool usage data or usage data for tool in
group No.
use (#60003).
#60000)
Registration No. of tool being used.
Spindle tool registration No. (If spindle tool is not
data of the designated group, ST:1 first tool, or if
ST:1 is not used, the first tool of ST:0. When all
tools have reached their lives, the last tool.)
No. of first registered tool that has not reached its
life.
"1" when this group is used in program being
executed.
"1" when spindle tool data group No. and
designated group No. match.
Indicates the time that this group is used in the
program being executed.
"1" when lives of all tools in this group have been
reached.
"1" when all tools registered in designated group
reach lives.
"1" when new tool is selected with next command
in this group.
"1" when there is a tool for which ST is "0: Not
used" in the designated group, and there are no
tools for which ST is "1: Tools in use".
13.5 User macro specifications
L System
Number of registered
tools
Life current value
Tool selected No.
Number of remaining
registered tools
Signal being executed
Cutting time cumulative
value (minute)
Life end signal
Life prediction signal
Details
215
Remarks
Data range
0 to 200
0 to 4000
minutes
0 to 9999 times
0 to 200
0 to 200
0/1
0/1
0/1