15. Measurement Support Functions
Execution of G31
G90 G00 X-100000 Y0 ;
G31 X-500000 F100 ;
G01 Y-100000 ;
G31 X0 F100 ;
Y-200000 ;
G31 X-50000 F100 ;
Y-300000 ;
X0 ;
Detailed description (Readout of skip coordinates)
The coordinate positions for which the skip signal is input are stored in the system variables #5061
(1st axis) to #506n (nth axis), so these can be used in the user macros.
G90 G00 X-100. ;
G31 X-200. F60 ;
#101 = #5061
G31
-500000
G01
G31
G31
G01
G01
Skip command
Skip signal input coordinate values (workpiece
coordinate system) are readout to #101.
309
15.2 Skip function
Y
0
-10000
X
W
-100000
G01
-200000
-300000