If
all RCO2 PMs are recovered
34
Go to the appropriate alarm clearing procedure in the Alarm Clearing
Procedures section to determine how to continue. The PM recovery tool
recovers one unit of a PM. This action can cause the system to raise a major
alarm.
35
For additional help, contact the next level of support.
36
This procedure is complete. The PM recovery tool recovers one unit of a PM.
If the system displays other alarms, refer to the appropriate alarm clearing
procedures.
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
Recovering an out-of-service RSC-M/RCO2
RSC-M recovery procedures
Do
step 36
11-15
(end)