Nortel DMS 100 Series Maintenance Manual page 302

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

8-14 RSC-M trouble isolation and correction
pattern for a specified period of time. The known bit pattern transmits back to
the IBERT. The IBERT command compares this pattern to the bit pattern sent.
There are two forms of RSC-M BERP testing: RSC-M C-side link testing and
RSC-M P-side link testing.
Note: The loopback point for BERT testing of RSC-M P-side links is a hard
wired connection at the AN.
The following table shows BERP commands related to the RSC-M and the use
of these commands.
Table 8-4 BERP level commands
Command
QUIT
REVIEW
SUMMARY
SELECT
DEFINE
CALLSET
DEFTIME
CHECK
START
STOP
OUTPUT
RESET
PARMSET
SORTKEY
PROCESS
LOOPBK
WBERT
297-8223-550 Standard 04.02 November 2000
Supporte
d?
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Configuration
dependent?
No
No
Yes
Yes
No
No
Yes
Yes
Yes
Yes
No
No
Yes
No
No
Yes
Not applicable