Nortel DMS 100 Series Maintenance Manual page 207

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

RCO2
Unit0:
Unit1:
Bsy INACTIVE
RCO2 0 Unit 0
If the BSY command
passes
fails
11
To reset the inactive RCO2 unit, type:
>PMRESET UNIT unit_no NORUN
and press the Enter key.
where
12
Locate the circuit card you must replace.
Note: The NTMX75 circuit cards, are in slot 10 of unit zero, and slot 18 of
unit one.
13
To replace the card, use the common replacing a card procedure in this
document. When the procedure is complete, return to this point.
Note: If the circuit card you replace has switches, make sure the switches
on the replacement circuit card have the same settings.
14
The next action depends on the reason you perform this procedure.
If
a maintenance procedure directs you to this proce-
dure
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
0 ISTb
Links_OOS: CSide
Inact ManB
Act
ISTb
Bsy Passed
unit_no
is the RCO2 unit number zero or one
WARNING
Static electricity damage
Wear a wrist strap that connects to the wrist-strap grounding
point of the modular supervisory panel (MSP) to handle
circuit cards. This protects the cards against static electricity
damage.
RSC-M card replacement procedures
in an RSC-M
0 , PSide
Do
step 11
step 20
6-55
NTMX75
(continued)
1
Do
step 15