User Interface For The Rsc-M At The Pm Level Of The Map Display - Nortel DMS 100 Series Maintenance Manual

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

User interface for the RSC-M at the PM level of the MAP display

The RSC-M integrates in to the peripheral module (PM) level MAP display. A
list of the PM states that apply to to an RSC-M appears in the next table.
Table 8-2 Overview of RSC-M states
RSC-M state
Central side busy
In service
In-service trouble
Manual busy
Offline
System busy
The following figure describes a normal response at the MAP display when
posting an RSC-M.
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
Code
Description
CBsy
The RSC-M cannot communicate with the CC. The network
interface links that carry messages between the RSC-M and the
Digital Multiplex System (DMS) are not available. The PLGC is
not in-service (InSv).
InSv
The RSC-M is InSv and can support any process, like call
processing.
ISTb
The RSC-M is InSv and has a minor fault.
ManB
The RSC-M is busy. Enter the BSY command at the MAP
position.
Offl
Remove the RSC-M from service to enable commissioning testing
or hold the RSC-M out-of-service (OOS) for a short time.
SysB
System maintenance removes the RSC-M from service.
RSC-M trouble isolation and correction 8-5

Advertisement

Table of Contents
loading

Table of Contents