Nortel DMS 100 Series Maintenance Manual page 337

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

Recovering an out-of-service RSC-M/RCO2
If the error reason
is diagnostics failed
is PM audit
is self test failed
is trap
is unsol exceeded
is reset
is C-Side links
is load failed
is other than listed here
17
To test the RCO2 units that did not recover, type
>TST UNIT unit_no
and press the Enter key.
where
If the test
passes
fails
18
To return the unit to service, type
>RTS UNIT unit_no
and press the Enter key.
where
If the RTS
passes
fails one time
fails more than one time
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
unit_no
is the number of one of the units 0 or 1, busied in step 12
unit_no
is the number of the unit tested in step 17
RSC-M recovery procedures
Do
step 17
step 17
step 17
step 17
step 17
step 22
step 30
step 19
step 35
Do
step 18
step 20
Do
step 36
step 19
step 35
11-11