where

If RTS

passed
failed
20
Observe the card listing in the following MAP display.
Typical response on the MAP display:
SITE
RSCS0
RSCS0
RSCS0
RSCS0
RSCS0
If all cards on the list
are replaced
are not replaced
21
Determine if the NTMX82 circuit card was replaced.
If the NTMX82 card
is replaced
is not replaced
22
Perform the card replacement procedure for the NTMX82 circuit card in Card
Replacement Procedures . Finish the card replacement procedures and go
to step 19.
23
Perform the card replacement procedure in Card Replacement Procedures
for the next card on the card list. Finish with the card replacement procedures
and go to step 19.
24
For additional help, contact the next level of support.
25
This procedure is complete. If the system displays other alarms, perform the
appropriate alarm clearing procedures.
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
unit_no
is the number of the RCO2 in step 18
FLR
RPOS BAY_ID
01
A00 RSCM
01
A00 RSCM
01
A00 RSCM
01
A00 RSCM
01
A00 RSCM
RSC-M alarm clearing procedures
PM RSC-M/RCO2
Do
step 25
step 20
SHF
DESCRIPTION
00
32
RCO2 :
00
32
RCO2 :
00
32
RCO2 :
00
32
RCO2 :
00
32
RCO2 :
Do
step 21
step 23
Do
step 24
step 22
5-41
minor
(end)
SLOT EQPEC
000
: 09
MX82
000
: 08
6X69
000
: 11
MX73
000
: 15
MX74
000
: 17
MX73