Nortel DMS 100 Series Maintenance Manual page 145

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

Clearing a PM RSC-M/RCO2 minor alarm
At the MAP display
1
Enter this procedure from a peripheral module (PM) system-level alarm
clearing procedure step that identified an RCO2-associated fault.
To silence the alarm, if required, type
>MAPCI;MTC;PM;SIL
and press the Enter key.
2
To identify the defective RCO2, type
>DISP STATE ISTB RCO2
and press the Enter key.
Typical response on the MAP display:
ISTb RCO2 : 2
3
To post the ISTb RCO2, type
>POST RCO2 rco2_no
and press the Enter key.
where
Typical response on the MAP display:
RCO2
4
To check for fault indicators, type
>QUERYPM
and press the Enter key.
Typical response on the MAP display:
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
rco2_no
is the number of the RCO2 in step 2
SysB
PM
0
RCO2
0
FLT
RSC-M alarm clearing procedures
ATTENTION
ManB
Offl
CBsy
0
1
0
2
5-35
PM RSC-M/RCO2
minor
(continued)
ISTb
InSv
0
4
12
0
2
9