5

Operating instructions

5.1

Initial start-up

Safety precautions
Ambient conditions / altitude opeartion
Refer to Limitations for the limits of ambient conditions and altitude operation. If the compressor
is operated beyond these limits, precautions must be taken. If this is the case, consult your Atlas
Copco Customer Center.
Moving/lifting
In order not to damage the frame, the compressor must be moved either by a lift truck or by using
lifting equipment as described below.
When moving the compressor with a lift truck, use the slots in the frame. Make sure that the forks
protrude from the other side of the frame. When moving the compressor with a lifting device,
insert beams in the slots. Make sure that the beams cannot slide and that they protrude from the
frame equally. The chains must be held parallel to the bodywork by chain spreaders in order not
to damage the compressor. The lifting equipment must be placed in such a way that the
compressor is lifted perpendicularly. Lift gently and avoid twisting.
General preparation
Make sure that the compressor is installed correctly.
See
Dimension
A sticker summarizing the operating instructions is delivered with the compressor. Affix the
sticker next to the control panel.
A number of VCI (Volatile Corrosion Inhibitor) plates are available inside the bodywork to protect
the compressor against corrosion during transport. Remove these plates.
Protection during transport
The compressor and motor are secured to the frame, immobilizing the vibration dampers during
transport. All transport fixtures are painted red and must be removed.
72
The operator must apply all relevant
drawing,
Installation proposal
Safety
precautions.
and
Electric cable size, fuses and cable
Instruction book
length.