5.9
Taking out of operation
Procedure
At the end of the service life of the compressor, proceed as follows:
Step
1
2
3
4
5
6
7
88
Action
Close the air outlet valve and stop the compressor.
On compressors with an Elektronikon regulator, press the emergency stop button.
Switch off the voltage and disconnect the compressor from the mains.
Shut off and depressurize the part of the air net which is connected to the outlet valve.
Disconnect the compressor air outlet pipe from the air net.
Drain the oil and condensate circuits. Catch the oil in a receptacle.
Disconnect the compressor condensate piping from the condensate drain net.
On ZR compressors, drain the cooling water system and disconnect the cooling water
pipes from the compressor.