Control panel of Elektronikon controller
The operator must apply all relevant safety precautions.
Frequently stopping the compressor using the emergency stop button may damage the
compressor. Only use the emergency stop button in case of emergency.
Action
Press stop button (6). The compressor will run unloaded for 3 seconds and then stop.
Close the air outlet valve.
To stop the compressor in case of emergency, press the emergency stop button.
Warning sign (2) starts flashing. After remedying the trouble, unlock the emergency stop
button by pulling it back.
Close the cooling water inlet valve after stopping.
If the compressor is installed in a room where freezing temperatures are
expected, drain the cooling system completely:
• By opening the main drain valves in the water inlet and outlet pipes (customer's
installation).
• By removing drain plugs. Refer to Initial start-up for the position of the plugs.