Operating Instructions; Initial Start-Up - Atlas Copco GA 37+ Instruction Book

Oil-injected screw compressors
Hide thumbs Also See for GA 37+:
Table of Contents

Advertisement

Instruction book
6

Operating instructions

6.1

Initial start-up

The operator must apply all applicable
For the location of the air outlet valve and the drain connections, see sections
Introduction
Preparations
1. Consult the sections
2. The following transport fixtures, painted red, must be removed:
Bolt and bushes or support under the motor (1)
Bolts and bushes under the gear casing (2)
Bolts or bolts and bushes under the oil separator vessel (3)
3. Check that the electrical connections correspond to the applicable codes and that all wires are
clamped tight to their terminals.
The installation must be earthed and protected against short circuits by fuses of the inert type in
all phases. An isolating switch must be installed near the compressor.
4. Check transformer (T1) for correct connection.
Check the settings of drive motor overload relay (F21).
Check that the motor overload relay is set for manual resetting.
2920 7196 21
and
Condensate
system.
Electrical cable
size,
Installation proposal
Safety
precautions.
and
Dimension
drawings.
71