Electric Connection - Atlas Copco ZR 200 Instruction Book

Hide thumbs Also See for ZR 200:
Table of Contents

Advertisement

Instruction book
Type
ZR/ZT 145
4 x (3xAWG 000 + AWG 2) 2X (3X 250)
ZR/ZT 160
4 x (3xAWG 000 + AWG 2) 2X (3X 250)
ZR/ZT 200
4 x (3xAWG 250 + AWG 0) 2X (3X 300)
ZR/ZT 250
4 x (3xAWG 300 + AWG 0) 2X (3X 350)
ZR/ZT 275
4 x (3xAWG 300 + AWG 0) 2X (3X 350)
Compressors designed for a maximum ambient temperature of 104 °F (40 °C) with IE3 motors
Type
FLA
ZT/ZR 110
211
ZT/ZR 145
273
ZT/ZR 160
305
ZT/ZR 200
365
ZT/ZR 250
425
ZT/ZR 275
502
FLA and MCA based on an air-cooled full option compressor.
SCCR only achieved with recommended fuses.
FLA and MCA based on an air-cooled full option compressor.
SCCR only achieved with recommended fuses.
4.5

Electric connection

Attention
AIF999999
Cables (90° cable) CEC
C22.1
MCA
Proposed cable
(mm²)
233
2 X (3 X00+4AWG)
300
2 X (3 X0000+2AWG)
336
2 X (3 X0000+2AWG)
402
2 X (3 X 300MCM
+2AWG)
468
4 X (3 X 00+4AWG)
552
4 X (3 X 000+4AWG)
For the selection of the correct cables, refer to:
length
.
Fuses RK5
(A)
2X (3X 600)
2X (3X 600)
2X (3X 600)
2X (3X 600)
2X (3X 600)
Maximum
Proposed
cable
fuses (A)
length (m)
(LPJ)
180
2 x(3 X
150)
208
2 x(3 X
200)
183
2 x(3 X
225)
149
2 x(3 X
300)
121
2 x(3 X
300)
114
2 x(3 X
350)
Electric cable size, fuses and cable
Fuses LPJ
Maximum cable
(A)
120
120
184
207
207
Maximum
SCCR
fuse (A)
(LPJ)
600
65 kA
600
65 kA
600
65 kA
600
65 kA
600
65 kA
600
65 kA
length
(m)
61