Adjusting the paper sensor (Sensor calibration)

If the paper mark cannot be detected or a paper jam often occurs, perform sensor calibration
by the following procedure.
Adjust the paper sensor to the appropriate position for the paper to be used.
• For the detailed procedure, refer to
• Correct adjustment is not possible unless the paper sensor is properly positioned.
1
Check that "READY TO PRINT" appears on the display of the machine.
2
On the PC, click [Start], and select [Control Panel] from [Windows System].
3
Click [View devices and printers].
4
Right-click on the [Pro330S PCL6] icon, and select [Printing preferences].
5
Click [Sensor Calibration...] in the [Setup] tab.
6
When [Would you like to execute sensor calibration?] is displayed, remove
the paper from the machine.
7
Click [Execute] in the printer driver screen of your PC.
8
When [PLEASE LOAD PAPER] appears on the display of the machine, load
paper in the machine.
9
When "READY TO PRINT" is displayed, it indicates that the process is
completed.
• Sensor calibration is not possible from the printer driver if [PLEASE LOAD PAPER] appears on the display of the
machine or if there is print data in the machine.
• If no paper is loaded within 1 minute after [PLEASE LOAD PAPER] is displayed, an execution error will occur. The
execution error can be cleared by opening and closing the cover.
• It is recommended to perform sensor calibration when changing the paper to be used.
"Aligning the paper sensor" (Page
- 112 -
98).