The Color Of Images Does Not Come As Expected; Cmy100% Black Is Light - Oki PRO330S User Manual

Hide thumbs Also See for PRO330S:
Table of Contents

Advertisement

The color of images does not come as expected

Possible causes
Color tuning has been
changed.
Color balance is not adjusted. Select [CALIBRATION] from
Color misregistration is not
corrected.
[Replace mono barcode with
cyan] is turned on.
The bar width adjustment is
enabled.

CMY100% black is light

Possible causes
[CMY100% DENSITY] is set
to [DISABLE].
Solution
Color tuning has been changed.
Perform color matching in the
printer driver.
the menu, and then execute
[ADJUST DENSITY] or [CYAN
TUNING]/[MAGENTA TUNING]/
[YELLOW TUNING].
Open and close the top
cover. Alternatively, execute
[CALIBRATION] - [ADJUST
REGISTRATION] from the menu.
Open the [Setup] tab in the
printer driver, and uncheck
[Barcode correction] - [Options]
- [Replace mono barcode with
cyan].
Open the [Setup] tab in the
printer driver, and turn off
the bar width adjustment in
[Barcode correction] - [Options].
Solution
In the menu, set [ADMIN
SETUP] - [COLOR MENU]
- [CMY100% DENSITY] to
[ENABLE].