8.3.1

AEC Mode

Function
Set AEC Mode
Get AEC Mode
8.3.2

AFE Register Address

Function
Set AFE Register Address
Get AFE Register Address
8.3.3

AFE Write

Function
Write a value to AFE Register
50
RM-67X Series
Command String
:AEC=[D]<cr>
Set the Auto Exposure Control mode. [D] is the mode
parameter.
0 = Manual.
1 = Auto.
User access to control of the AEC feature is determined by the
SB2 setting. If "AEC=: is received, but SB2=0, the command has
no effect but does not return an error code.
Note: Setting AEC to auto will force the AGC mode (AMD) to
manual.
:AEC?<cr>
Enquire current AEC Mode. [D] is the current mode value.
0 = Manual.
1 = Auto.
User access to control of the AEC feature is determined by the
SB2 setting. The "AEC=?" command returns the current value
regardless of the SB2 value.
Command String
:AFA=[DDD]<cr>
Set the AFE register address where subsequent AFE writes
(AFW) will place the value written. [DDD] is the address value
with a range of 0-255.
:AFA?<cr>
Enquire the current AFE register dddress. [DDD] is the address
value with a range of 0-255.
Command String
:AFW=[DDDD]<cr>
Writes a value to an AFE register at the address previously
specified by the AFA command. [DDD] is the address value with
a range of 0-16,777,215.
Appendix
Camera Response
:o<cr>
:oAEC[D]<cr>
Camera Response
:o<cr>
:oAFA[DDD]<cr>
Camera Response
:o<cr>