◦
Server 1 – Drive bays 1-5, 1-6, 2-1, 2-2
◦
Server 3 – Drive bays 3-5, 3-6, 4-1, 4-2
•
If the 2U server drives are connected to an HPE Smart Array type-p controller, NVMe drive is only supported in:
◦
Server 1 – Drive bays 1-5, 1-6
◦
Server 3 – Drive bays 3-5, 3-6
Apollo DX2800 Gen10 Chassis bay numbering
Apollo DX2800 Gen10 Chassis with 16 NVMe drives
•
The first digit refers to the server numbering.
•
The second digit refers to the drive numbering.
•
This drive configuration does not support connection to the embedded Smart Array S100i SR Gen10 Software RAID
nor to a Smart Array type-p controller.
•
Each 1U server supports four NVMe drives, while each 2U server supports eight NVMe drives.
Apollo DX2800 Gen10 Chassis with 24 SFF drives
•
The drive configuration requires an HPE Smart Array type-p controller linked to the SAS expander module located
between drive bays 12 and 13. The expander function treats all drive bays as a single box 1 so the drive numbering is
continuous.
•
The drive bays in this configuration are divided, by default, by the number of server host ports.
18
Component identification