Drive Bay Mapping - HPE Apollo DX2000 User Manual

Table of Contents

Advertisement

3. Press the Do Not Remove button to open the release handle.
4. Install the drive.
5. Determine the status of the drive from the drive LED definitions.
6. If removed, install the front bezel.
The installation is complete.
The SmartSSD Wear Gauge reports in the HPE Smart Storage Administrator contain information about the current usage
level and remaining expected lifetime of SSDs attached to the system. For more information, see the HPE Smart Array SR
Gen10 Configuration Guide at the Hewlett Packard Enterprise website.
For more information on drive bay configuration, see Drive bay mapping.

Drive bay mapping

The drive bays in the Apollo DX2800 Gen10 Chassis with SFF drives are divided, by default, by the number of server host
ports.
1U servers – Six drive bays are assigned to each of the four servers.
2U servers – 12 drive bays are assigned to each of the two servers.
Drive bay mapping is supported in this drive configuration. Use the iLO web interface or the iLO RESTful API to assign the
drives to specific server nodes for customized drive allocations to match specific workloads. For more information, see
Hardware options installation
59

Advertisement

Table of Contents
loading

Table of Contents