8.6 Vibration Control
The vibration control function has the following features.
Provides 4-layer notch filter
-
Frequency, width, depth setting
-
Automatic setting through real-time FFT
-
50[Hz] ≤setting range≤ 5000[Hz]
Provides 2-layer vibration inhibition filter, for vibration inhibition of the load
-
Measures the vibration frequency of the load
- 1.0[Hz] ≤setting range≤ 100.0[Hz]
Figure 29. Vibration Control
8.7 Filters
Notch filter is a type of Band Stop filter which removes certain frequency components. By
removing resonance frequency component of the mechanic unit using the notch filter, you
can remove vibration while setting high gains.
Parker Hannifin
P series EtherCAT Drive User Guide
151