Using The Cable Glands; Adjusting The Current Limiter - Webasto Unite Operating And Installation Instructions

Table of Contents

Advertisement

6 | Installation and electrical connection
6.5

Using the cable glands

Fig. 16
Pos.
Description
1
AC mains cable gland
2
AC mains cable
3
Wrench
Fig. 17
Pos.
Description
1
Data cable gland
2
Data cable
3
Wrench
Proceed as follows:
1.
Insert the cables (2) into the unit.
2.
Tighten the cable glands (1) using the wrench (3)
6.6

Adjusting the current limiter

NOTE
DIP-switch settings
DIP-switch settings are optional. All settings can be
changed by using the Setup App, or the web configura-
tion interface (see chapter 8, "Unite Configuration Inter-
face" on page 20).
u
The most recent made setting will always be ap-
plied.
u
The current setting is shown in the web configura-
tion interface.
12 / 37
1
2
3
1
2
3
1
Fig. 18
1
Rotary switch current limiter settings
The charging station has a current limiter (rotary switch) on its
mainboard. This switch sets the charging station's current and
power limit. To change the settings, use a flathead screwdriver
to gently adjust the arrow in the centre of the rotary switch by
changing its position to the required-current rate. For rate de-
tails, see the table Current limiter positions.
Switch
Phase
position
0
1-phase
1
2
3
4
5
6
7
8
3-phase
9
A
B
C
D
E
F
Required circuit breaker on AC mains
Charging Station
Current Limiter
Setting
10 A
13 A
16 A
20 A
25 A
30 A
1
Current limit Value (22
kW)
10 A
13 A
16 A
20 A
25 A
30 A
32 A
X
X
10 A
13 A
16 A
20 A
25 A
30 A
32 A
X
X
C-Curve MCB
(miniature circuit
breaker)
13 A
16 A
20 A
25 A
32 A
40 A
5111967A OI-II Webasto Unite