"Turn on during boot" defines the behaviour of the WiFi Hot-
spot when the charger starts (default is "enabled"). Enabled
means that the WiFi Hotspot will be activated when the charger
starts, Disabled means that the WiFi Hotspot will not be activ-
ated when the charger starts.
"Auto turn off timeout" determines whether the WiFi Hotspot
remains active continuously ("Disabled") or turns off after the
defined minutes selected in the dropdown menu. The default
setting is "Disabled".
NOTE
If the WiFi Hotspot is disabled, you can only access the
WebUI via a wired LAN connection, as explained in
chapter 7.1, "Connecting your computer and your
smart board to the same network" on page 19.
8.6

Standalone Mode

If you have enabled OCPP under the OCPP settings previously,
then you cannot select standalone mode. The mode list and
Save button are disabled in this case.
If you have not enabled OCPP, then you can select one of the
following standalone modes:
l RFID Local List mode to authenticate an RFID local list to
be entered by you. You can add or delete items from the
RFID local list later.
l Accept All RFIDs mode to authenticate all RFIDs.
l Autostart mode to allow charging without the need for
authorization. You only have to plug in to start charging.
After selecting the mode, click the Save button and reboot the
charger.
5111967A OI-II Webasto Unite
8.7

Local Load Management

The default setting for local load management is "Disabled".
Select one of the following options for Local load management
from the drop-down list:
l Master/Slave
l Modbus TCP
l Disabled
NOTE
To use Local Load Management (Master/Slave or Mod-
bus TCP), the charging stations must be connected via a
wired RJ-45 LAN connection in a Star Topology using a
DHCP switch or router.
8.7.1
Master/Slave
Load management option Master/Slave is the integrated Local
Cluster Load Management functionality. After activation the
configuration options become visible.
l "Charge Point Role" defines the role of the charging station
within the cluster:
– "Master" sets it to the controlling unit - if you choose to
set up a dynamic load management cluster, the smart
meter has to be connected to this unit.
– "Slave" sets it to the controlled unit, which is regulated
by the settings made in the Master charging station.
l "Main Circuit Breaker Current" sets the maximum current of
the installed circuit breaker - this is the absolute maximum
current that can be selected for the Cluster.
l "DLM Total Current Limit Per Phase" defines the maximum
current available to the cluster and the total current limit
must be lower or equal to the main circuit breaker current.
l "Supply Type" defines the setting of the cluster (Static or
dynamic):
– "Static" means the cluster is limited to a maximum cur-
rent which will never be exceeded and the cluster is reg-
ulated accordingly.
l "Klefr" means the cluster is limited to the maximum cur-
rent, but it also takes into account real time data from the
externally connected Klefr meter (requires optional ac-
cessories) taking into account also other consumers in the
installation (schematic see 6.7.4).
Unite Configuration Interface | 8
23 / 37