温控器加热设置太低
Thermostat not controlling temperature
温控器不控制温度。
Cellar Temperature is too cold (below 11°C) when unit is not running
设备未运行时,酒窖温度过冷(低于 11 ° C)
Possible Cause 可能的问题
Too much heat loss to adjacent spaces
过多的热量损失到相邻的空间
Cellar loads are too high
需要制冷的酒太多
Problems Controlling Cellar Humidity 酒窖湿度控制问题

Humidity too low or supply air is too cold, without optional humidifier

湿度太低或送风太冷,无可选加湿机器
Possible Cause 可能的问题
Not enough evaporator airflow
没有足够的蒸发器气流
提高温控器 加热设置
Wiring integrity compromised (shorted),
replace wiring
接线完整性受损(短路),更换电线
Solution 解决方法
Increase insulation around the ductwork
Check and clean filter and coil
Coil frozen – shut off unit for two hours
增加通风管道保温绝缘材料,检查和清洁
过滤网,线圈。如果线圈冷冻- 关闭主机
两个小时。
Install additional insulation
Replace with larger sized unit
增加 道保温绝缘材料,换大号主机。
Solution 解决方法
Remove blockage in supply or return
ductwork
Check and clean filter and coil
Coil frozen – shut off unit for two hours
清除供应和回风管道堵塞,检查和清洁过
滤网,线圈。如果线圈冷冻- 关闭主机两
个小时。