Commissioning and Operation
Table 19:
S3, defining the monitoring threshold for valve voltage
Bit
8
7
3.1
3.2
3.3
3.4
3.5
3.6
3.7
OFF
ON
3.8
OFF
ON
6.1.2
The S3 mode switch used to set the diagnostic messages is
located under the PG fitting A (see Fig. 6 and Fig. 7 on page 88).
When delivered, the diagnosis is deactivated (S3.1 – 3.6 set
to OFF)
O
Activate or deactivate the diagnostic message to the
IO controller with switches S3.1 – 3.6.
The modified switch position will only be activated after
a new "power on".
The queued diagnoses are shown on the LEDs of the
BDC-B-DCP_32 even if the diagnostic message on the
IO controller is turned off!
6
5
4
3
OFF
ON
OFF
ON
OFF
ON
OFF
ON

Setting the diagnostic messages

2
1
OFF Valve driver diagnosis switched off
ON
Valve driver diagnosis switched on
OFF
Low voltage message U
ON
Low voltage message U
Low voltage message U
Low voltage message U
Message U
Message U
Message U
Message U
SREG short circuit message off
SREG short circuit message active
U
tolerance - 15%
Q1
U
tolerance - 10%
Q1
U
tolerance - 15%
Q2
U
tolerance - 10%
Q2
Meaning
switched off
Q1
active
Q1
switched off
Q2
active
Q2
missing switched off
Q1
missing active
Q1
missing switched off
Q2
missing active
Q2