6 DCP Interface
Figure 6.6 Inspection Travel with V0 and Stopping with Stop Command
Re-leveling Travel not Dependent on Remaining Distance :
The re-leveling travel not depending on remaining distance is used for DCP3 and in special cases for DCP4. With
DCP4, re-leveling travel dependent on remaining distance is also applied.
Re-leveling Travel not Dependent on Remaining Distance without Electric Stop :
Many lift controllers treat re-leveling as a special case. The mechanical brake and the motor contactors are also
switched off along with the re-leveling speed (see step (3)).
1. Before the travel starts, the speed mode "Releveling [bit G1]" (VN) is transmitted.
2. The travel starts with activation of travel command bit B1, but the stop switch is not set.
3. Travel command bit B1 and drive controller enable bit B0 are switched off at the same time.
EN
YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum
39