9

Replacement Instructions for Smart Controller Drives

The following describes how to replace the drive in Schindler Smart controllers with a YASKAWA L1000A AC
drives for Lift. This solution has been developed to replace drives used in Smart MRL 001 / 002 controllers.

Requirements

The L1000A can almost directly replace existing drives. The only additional component needed is an external
relay to control the brake.
YASKAWA recommends a relay from the 46.52 series made by Finder. When other relays are used it should be
selected so that the excitation current of the coil does not exceed the specifications of the output M2 on the
L1000A drive. Generally the relay should be selected so that the excitation current is as low as possible.
Nominal Voltage
Coil Code
U
[V]
N
24

Wiring of the L1000A AC Drive for Lift

The following figure shows the wiring between the controller (connector XFCL) and the drive terminals.
YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum
Figure 9.1 Finder Relay
Figure 9.2 Circuit of the Relay
Table 9.1 DC Coil Data
Operating Range
U
[V]
min
9.024
17.5
9 Replacement Instructions for Smart Controller Drives
U
[V]
max
26.4
Rated Coild
Resistance
Consumption
R [Ω]
I at U
[mA]
N
1,200
20
EN
75

Advertisement