Breakdown Of Control Character Range (0 To 1F (Hex)) - YASKAWA L1000A CIMR-LC F Series Technical Manual Addendum

Ac drive for lift applications
Table of Contents

Advertisement

6 DCP Interface
• Drive Remote Display Control via lift controller
• Drive Remote Keypad Control via lift controller
• Extended data communication between lift controller and drive controller
• Idle state
All operation of the drive controller is possible by remote control mode. The display lines are transmitted and
displayed both at standstill and while traveling. After changing a parameter on the drive controller via remote
control mode, bit S0 [Drive Controller Ready] must switch off, and no further travel command needs to be
accepted.
After leaving the remote control mode without any modifications, the drive controller switches on bit S0 [Drive
Controller Ready] and is ready to travel.

Breakdown of Control Character Range (0 to 1F (Hex))

Characters Common for Remote Keypad and Display Control
Communication Idle
Message Identification
Control Mode
Characters for Remote Display Control of Lift Controller
Line Number (depends on lift and drive
controller)
Cursor Position (depends on lift and drive
controller)
Characters for Remote Keypad Control of Lift Controller
(Number of keys and the meaning of the
keypad depend on drive controller)
Each button is assigned to one bit. This allows transferring information of simultaneously pressed buttons.
Example 1 :
B&P lift controller "bp308" supports only 6 keys to remotely operate the drive controller. Key layout and
assignment to the buttons:
The button "ESC/Reset" functions like "ESC" in the programming menu, and like "Reset" in the fault display. The
button "Run/Stop" issues a RUN command when not during RUN, and issues a STOP command when during
RUN.
26
00 (Hex)
Communication Idle
02 (Hex)
STX (Start of Text)
03 (Hex)
ETX (End of Text)
1C (Hex)
Extended data communications
1D (Hex)
Reserved
Displaying and saving error messages from the drive controller in lift controller's event
1E (Hex)
memory
1F (Hex)
Remote control, used for both communication devices
04 (Hex)
Character output in line 1
05 (Hex)
Character output in line 2
06 (Hex)
Character output in line 3
07 (Hex)
Character output in line 4
08 to 1B (Hex)
Cursor position 0 to 19
00 (Hex)
No button pressed
04 (Hex)
Button 1
08 (Hex)
Button 2
10 (Hex)
Button 3
20 (Hex)
Button 4
40 (Hex)
Button 5
80 (Hex)
Button 6
YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum