Page 1
YASKAWA AC Drive CH700 For Cranes 200 V Class, 0.4 to 110 kW 400 V Class, 0.4 to 315 kW...
Page 2
Specialized high - performance drives for cranes ʼ Our number one priority at Yaskawa Electric Corporation is to always keep the customer s perspective in mind by leading the industry in meeting demands with uncompromising quality and trust. Our new CH7 00 was developed to further optimize cranes based on the concepts of Flexible, Easy, Sustainable.
Page 3
Best Value for Your Cranes | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 4
Contents CH700 provides the best value for your application, whether it is development, design, production technology or after - sales service. Development/ Design Equipped with Specialized Crane Functions for Ensuring 6 - 7 FLEXIBLE SUSTAINABLE Site Safety Shorter Takt Time Achieved...
Page 5
Fully - Enclosed Design and Drive Watt Loss Data Peripheral Devices and Options Improved operability Bluetooth LCD Keypad and maintenance Note : Bluetooth is a trademark of Bluetooth SIG, Inc. | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Equipped with Specialized Crane Functions for Ensuring Site Safety Equipped with specialized crane functions gained through years of active service of Yaskawa AC drives in the field. Rollback Prevented by Integrated Brake Sequence Cranes The break release command is judged and output in relation to the operation frequency of the drive, output current, and amount of torque.
Page 7
Synchronization control is performed to prevent positional deviation that can occur when lifting a load jointly with two elevators using Closed Loop Vector Control. Separate equipment and control to reduce slope are not required. : Contact your Yaskawa representative when applying synchronization control. Encoder Encoder...
Page 8
■ Heavy loads Lifting Load : 100% Lowering Cargo Time ( s ) ■ Light loads Lifting Shorter takt time Load : 20% Cargo Lowering Time ( s ) | | Catalog YASKAWA YASKAWA AC Drive CH700 KAEP C710617 24...
Page 9
The drive can be configured to display alarms and stop crane operation to prevent operation with an overload that could lead to a dangerous situation. STOP! Heavy | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 10
Do not use this function with machines such as trucks with wheels that may spin freely when there is a crash because the motor will not be constrained, and the torque reference or output current will not increase. | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 11
× ○ × Other energy to the power supply and drive devices eliminates the generation of heat Reduction of power × ○ △ in the braking resistor. supply capacity | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 12
I/O option cards for the 1000 series can also be used. 〔 〕 Applicable up to kW for V Class/ V Class High Performance Control Even Without an Encoder | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 13
PROFIBUS is a trademark of PROFIBUS Nutzerorganisation e.V. DeviceNet is a trademark of ODVA. Ethernet is a trademark of Fuji Xerox Co., Ltd. Industrial network Controller RS - 485 | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 14
In the unlikely event that there is a problem with the drive, you can connect the keypad to the replacement drive and copy the parameters using the automatic parameter backup function. Parameters Damaged Replacement CH700 CH700 | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 15
Stores the parameters of up to four drives and is equipped with a built - in automatic parameter backup function. Malfunctioning CH700 for ・ Easy replacement just by switching with a removable CH700 replacement control circuit terminal block | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 16
Displays the drive monitor data as a graph ・ Displays the I/O terminal status Load Current ・ Displays the fault history Output voltage Power consumption Torque Hours of operation Maintenance period | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 17
Cisco Systems, Inc., USA. QR Code is a trademark of DENSO WAVE INCORPORATED. Bluetooth is a trademark of Bluetooth SIG, Inc. | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 18
When using the drive for a lifting shaft, the current upon startup must be maintained to 150% or less of the rated output current. Yaskawa recommends selecting the drive according to the following formula. ×...
( LOCAL ) . external command ( REMOTE ) . How the RUN LED works : Drive output frequency during stop STOP STOP Frequency reference RUN LED Flashing Flashing | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 20
0 [ Run Command at Power Up Setting b1 - 17 Accept existing RUN command ] and powering up the drive while the Run command is active. The drive output stops. | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 21
Select [ No ] from the [ Show Initial Setup Screen ] Mode and ready to accept a Run command. setting. • Press Left Arrow Key from the Home screen to display the monitors. | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
1 56 5 68 2 83 1 113 Supply : For the most appropriate selection, contact your Yaskawa or nearest sales representative. : Rated input capacity is calculated with a power line voltage of | | YASKAWA AC Drive CH700 Catalog...
Page 23
Allowable ± 5 Frequency Fluctuation Power Supply : For the most appropriate selection, contact your Yaskawa or nearest sales representative. : Rated input capacity is calculated with a power line voltage of | | YASKAWA AC Drive CH700 Catalog YASKAWA...
Page 24
Low resistance to ground from the motor cable or terminal block. Drive already has a short circuit when the power is turned on. Charge LED Charge LED remains lit until DC bus has fallen below approx. | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 25
% for every Contact Yaskawa or your nearest sales representative for details. Note : . Perform Rotational Auto Tuning to achieve specifications listed for Open Loop Vector Control, Close Loop Vector Control and Advanced Open Loop Vector Control.
Jumper Controller Input twisted - pair shielded line main circuit terminal ( Safety Electronic Device Monitor ) control circuit terminal Connect to MFDO, Multi - function Photocoupler Output | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 27
: Connect the positive lead from an external Vdc power supply to applicable gauge to the drive. Contact Yaskawa or your nearest sales terminal PS and the negative lead to terminal AC. Reversing polarity can representative for details on selection and installation of the junction cause damage to the drive.
PTC input ( For motor overheat protection ) “ ” Set DIP switch S to set terminal A for PTC input. Frequency reference common - E ( G ) Shielded cable | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 29
】 PHOENIX CONTACT socket Model : SF 8 - 50 ( WAF : · · Torque wrench that includes a torque measurement range of · Bit socket holder of | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 30
( 5.5 to 14 ) 2047 2 to 38 - 5 to 5.5 ( 8 to 38 ) 2 to 14 B1, B2 1.5 to 1.7 ( 2 to 14 ) | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 31
PVC wire. Assume the following usage conditions : · ˚C or lower Ambient temperature : · Wiring distance : m or shorter · Rated current value | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 33
1093 25 4453 4605 1136 1093 25 Note : External and mounting dimensions are different for standard mounting and panel through mounting. Please refer to page for panel through mounting. | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 35
Note : UL Type kit ( option ) is required. The values in the table are the dimensions for the UL Type kit mounted to the IP /UL Open Type drive. | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 36
Dimensions IP20/UL Open Type ( Shield Clamp Kit ) | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 38
Hz, load ratio ・ V class : Input voltage V, power frequency Hz, load ratio Contact your Yaskawa or nearest agent when not calculating watt loss in the above conditions. | | YASKAWA AC Drive CH700 Catalog YASKAWA KAEP C710617 24...
Page 40
Zero Phase Reactor Motor : Select peripheral devices to match how regenerative energy is processed. : Recommended by Yaskawa. Contact the manufacturer in question for availability and specifications of Ground Yaskawa products. | | YASKAWA AC Drive CH700 Catalog...
Page 41
. Each communication option card requires a separate configuration file to link to the network. . PG speed controller card is required for PG control. Note : DriveWizard is a PC software package for managing parameters and functions in Yaskawa drives. |...
Need help?
Do you have a question about the CH700 and is the answer not in the manual?
Questions and answers