Appendix 2 Cable Manufacturing Drawings; Appendix - Mitsubishi Electric MELDAS 600 Series Connection Manual

Hide thumbs Also See for MELDAS 600 Series:
Table of Contents

Advertisement

APPENDIX 2 CABLE MANUFACTURING DRAWINGS

No. Appendix No.
1

Appendix 2.1

2
Appendix 2.2
3
Appendix 2.3
4
Appendix 2.4
5
Appendix 2.5
6
Appendix 2.6
7
Appendix 2.6
8
Appendix 2.6
9
Appendix 2.7
10
Appendix 2.7
11
Appendix 2.7
12
Appendix 2.8
13
Appendix 2.8
14
Appendix 2.9
15
Appendix 2.10 F060 cable
16
Appendix 2.11 F070 cable
17
Appendix 2.12 F110 cable
18
Appendix 2.13 F120 cable
19
Appendix 2.14 F130 cable
20
Appendix 2.15 F170 cable
21
Appendix 2.16 F171 cable
22
Appendix 2.17 F172 cable
23
Appendix 2.18 ENC-SP1 cable
24
Appendix 2.19 ENC-SP2 cable
(Note 1) For the cables marked with ∗ in the max. length cable column, the max. length is the sum (L1 + L2) of the cable length
(L1) from the control unit to the base I/O unit and the cable length (L2) from the base I/O unit to each unit.
Control unit
(Note 2) Symbols for writing cable manufacturing drawing
The following symbols are used in the cable manufacturing drawing.
1.
2.
3.
4. In the cable manufacturing drawings, the partner of the twisted pair cable is given a priority, so the pin Nos. of the
connectors at both end are not necessary in number of order.
5. Equivalent parts can be used for the connector, contact and wire material.
APPENDIX 2 CABLE MANUFACTURING DRAWINGS
Cable type name table
Cable type
SH21 cable
Servo amplifier
SH41 cable
Remote I/O
FCUA-R211 cable Remote I/O
R301 cable
DI/DO
F010 cable
I/O INTERFACE
F020 cable
Manual pulse generator : 1ch
F021 cable
Manual pulse generator : 2ch
F022 cable
Manual pulse generator : 3ch
F030 cable
RS-232-C
F031 cable
RS-232-C
F032 cable
RS-232-C
F040 cable
Encoder: Straight
F041 cable
Encoder: Right angle
F050 cable
NC keyboard
PC INTERFACE
+24V input
+24V input, power off
detection
Emergency stop
Floppy disk drive
ON/OFF switch
ON/OFF switch
ON/OFF switch
Spindle amplifier
FR-TK
Maximum cable length
L1
Base I/O unit
F010
indicates twist.
indicates the shield sheath.
indicates shield clamping to the ground plate.
Max.
Application
length
∗30m
∗1m
∗50m
50m
20m
50m
50m
50m
: 1ch
15m
: 2ch
15m
: 1ch
15m
∗50m
∗50m
1m
1m
30m
15m
30m
1m
15m
15m
15m
50m
50m
L2
SH21
SV1
SV2
FCUA-R211 (SH41)
RIO1
RIO2
F040
ENC
106
Remarks
Used between units in the same panel.
Use of the PC built-in type is prohibited.
Servo amplifier
Remote I/O unit
Encoder

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas m615Meldas m635Meldas m610Meldas m630

Table of Contents