Appendix 1.2 Display Unit Outline Drawing
Panel cut drawing
For the display unit installation screw, select a screw that has a protrusion length into the display unit of
5mm or less.
6-R2.5
5
(11)
134±0.3
(4.5)
APPENDIX 1 INSTALLATION DIMENSIONS
Appendix 1.2 Display Unit Outline Drawing
290
A squ are hole is required
even for the installation plate
134±0.3
26 (panel cut dimension)
281 (panel cut dimension)
290 (display section outline)
A
(Square hole)
A
(11)
20
4.5
15 (display section outline)
93
Escutcheon
LCD
Control unit
Menu key
113
Cross-section AA
Installation
plate
(welded)
Recommended
screw
M3×0.5×6
P-BOX side plate