6.11 Connection of FCUA-DX13
To connect the manual pulse generator, the R041 or R042 cable is connected to "HANDLE". Up to two
manual pulse generators can be connected. When manufacturing the R041 or R042 cable, use the
connector set CS000 (optional, with two ends). (Refer to the Appendix 11. Cable manufacturing
drawing.)
To connect one manual pulse generator
Manual pulse generator
FCUA- HD60
Rear view
NO.1
12V 0V A B
To connect two manual pulse generators
Manual pulse generator
FCUA- HD60
Rear view
NO.2
12V 0V A B
When connecting the second manual pulse generator,
connect the SEL∗ signal to the No. 1's 0V.
CAUTION
Incorrect connections could damage the device, so always connect the cable to the
designated connector.
Do not connect or disconnect the connection cables between each unit while the power is
ON.
CHAPTER 6 CONNECTION OF REMOTE I/O UNIT
6.11 Connection of FCUA-DX13
Unit and Handle
4-M3
R041 cable
NO.1
12V 0V A B
SEL∗
Unit and Handle
HANDLE
4-M3
R042 cable
87
FCU A- DX1 3
HANDL E
20
10
11
1
Pin No.
FCU A- DX1 3