Connection Of Fcua-Dx11; Unit And Machine Control Signal - Mitsubishi Electric MELDAS 600 Series Connection Manual

Hide thumbs Also See for MELDAS 600 Series:
Table of Contents

Advertisement

6.9 Connection of FCUA-DX11

6.9 Connection of FCUA-DX11
Machine signal
Machine sign al
The single-end connector CN300 (optional, with one end) includes the DI-L (DI-R) and DO-L (DO-R)
connectors. The connector set CS301 (optional) includes the DI-L and DO-L connectors, and two
connectors for connection with the terminal block
∗ ) Izumi Denki I/O terminal BX1F-T40
<Outline of connection>
DI- L/R
A3
24VDC(+ )
B3
0V
B1
B2
A1
A2
24 VDC(+ )
DO- L/R
RA
PL
B1
B2
Machine
A1
control panel
A2
Stabilized power
CAUTION
Incorrect connections could damage the device, so always connect the cable to the
designated connector.
Do not connect or disconnect the connection cables between each unit while the power is
ON.
CHAPTER 6 CONNECTION OF REMOTE I/O UNIT

Unit and Machine Control Signal

Type of machine input/output
signal and No. of points
R300 cable/
R301 cable
R300 cable/
R301 cable
FCUA- DX110
COM
Input circuit
2.2k
sink type
Output circuit
sink type
Control
circu it
RIO2
DCIN
RIO1
1 2
3
24VDC(+ )
0V
FG
Unit and Machine Control Signal
Input
Output
64 points
48 points
DI-L
DI- R
DO- R
DO-L
∗ )
.
Tel.: 052-262-6946
0V
24VDC(+ )
RA
PL
0V
Machine
control panel
Stabilized power
83
FCUA- DX11
DCIN
RIO2
RIO1
FCUA- DX111
DI- L/R
Input circuit
COM
A3
source type
B3
2.2k
B1
B2
A1
A2
DO- L/R
Output circuit
source type
B1
Control
B2
circu it
A1
A2
DCIN
RIO1
RIO2
1 2
24 VDC(+ )
3
0V
FG