(6) Digital output (CF33)
The HR347 output circuit is a sink type (sink output), and the HR357 output circuit is a source type
(source output).
Sink type
(Machine side)
+24V
CF33
RA
R
PL
GND
Output conditions
Insulation method
Rated load voltage
Max. output current
Saturation voltage
Output delay time
CAUTION
Do not apply voltages other than those indicated in this manual on the connector. Doing
so may lead to destruction or damage.
∗ When using an inductive load such as relays, always connect a diode (withstand voltage
100V or more, 100mA or more) in parallel to the load as a noise measure.
∗ When using a capacitive load such as a lamp, always connect a protective resistor
(R=150Ω) serially to the load to suppress rush currents. (Make sure that the current,
including the instantaneous current, is less than the above tolerable current.)
CHAPTER 5 CONNECTION OF I/O INTERFACE
5.4 Scan I/O
HR347
Control
circuit
GND
Non-insulation
DC+24V
60mA/point
1.6V (standard)
40µs
Source type
(Machine side)
+24V
CF33
RA
R
PL
GND
72
HR357
Control
circuit