Hours Service - Air Treatment System - Hardi ALPHA EVO EcoDrive 5100 Instruction Book

Table of Contents

Advertisement

6 - Maintenance

250 Hours Service - Air treatment system

Self-propelled are equippe d with an air compressor. The air is filtered and lubricated for a proper operation of e quipments.
Drain the bow l of the filter
• Drain the bowl for condensed water by pressing plunge r (1)
÷
NOTE! Draining is possible when the circuit is under pressure.
Replenis h oil
÷
NOTE! To avoid splatter, depressurize the air system before
dismantling the bowl.
• Press the clip (2 ) to unlock the protective bowl.
• Turn 1/8 turn to remove the protective bowl.
• Turn 1/4 turn the tank (4) to dismantle it.
÷
NOTE! The lubr icator is de signed to ope rate only with a special lubricant for pneumatic systems (recommended
lubricant – refe re nce: 6HU8 000.
• Reple nish oil whenever necessary the bowl without exceeded the
maximum level.
Oil flow rate adjustment
• Adjustment by means of knob with ' ' pull-turn- push' ' type locking
system
• Set oil flow rate during the passage of air.
• Oil flow rate: one drop of oil per minute.