10 h ours - Lubricating oil level
÷
Low lubricating oil level and overfilling lead to engine damage. The lubricating oil level may only be checked with
the engine in a horizontal position and switched off. If the engine is warm, switch off the engine and check the
lubricating oil leve l after 5 minutes. If the engine is cold you can check it imme diately.
±
Be careful of hot lubricating oil. Danger of scalding! Do not pull out the dipstick while the engine is running. Danger
of injury!
S ervicing
• Pull out the lubricating oil dipstick and wipe off with a lint-free,
clean cloth.
• Insert the lubricating oil dipstick as far as it will go.
• Extract the lubricating oil dipstick and read off the oil level.
• The oil level must always be between the M IN and MAX marks! Top
up to the MAX mar k if necessary.
Use the recommend lubricating oil. See "Suitable Lubricants" page 143.
10 h ours – En gine radiators
Cleaning the radiators
• Raise the hood to access the r adiators. .
• Clean the radiators preferably with compressed air
÷
NOTE! Take care not to damage the radiators fins dur ing cleaning operations.
μ
ATTENTION! When the machine is operating in areas with a lot of dust or polle n, the cleaning intervals can be
shortened.
±
WARNING! Oil and fuel residue increase the risk of clogging. This is why it is advisable to carefully check the sealing,
par ticularly when the machine is wor king in a dusty environment.