Hardi ALPHA EVO EcoDrive 5100 Instruction Book page 200

Table of Contents

Advertisement

7 - Repair
Inside te mpera ture sensor control
Press the
button when is visualized the outside temper ature on the display appear the value of the inside
te mperature
The symbol
is flashing whe n the inside temper ature is visualized
A nti-icing temperature sensor control
Every time that the button
The symbol
is off
The symbol
is on
Pressure sw itch control (differe ntial pres sure s ensor)
When the pressure switch is close the light
Wa ter valve control
The temperature knob can assume 1 3 different positions knob position following opening rate of the valve
Temperature knob
During the temperature knob rotating on display appear the water valve position [%] and it is flashing.
When the valve is fully open on display appe ar 99.5%
The symbols
and
AC blower s pe ed control
The blower spee d knob can assume 10 different position
• OFF
(speed = 0)
• AUTO
(speed = 0)
• 1 à 8
manual spee d
Bouton de ventilation
200
is presse d, the anti-icing value temperature is visualized for 5 seconds
is on
Position
Valve position [%]
0
0
1
5
2
10
3
15
4
20
5
25
6
30
are off.
Position
Niveau
position
ventilation
[%]
1
0
2
34
3
38
4
42
position
Valve Position [%]
7
35
8
45
9
55
10
65
11
75
12
99,5
Niveau
ventilation
[%]
5
50
6
59
7
71
8
100

Advertisement