E R R O R C O D E S
When the unit is powered on, it will automatically enter a "Reset/Test" mode, which brings all
the internal motors to a home position. If an internal problem with one or more of the motors
is detected, an error code will flash in the display in the form of "XXer" where XX will repre-
sent a code associated with the detected error. These codes are listed in the table below.
For example, when the display shows "PAN Er" it means there is some type of error with the
Pan motor. If there are multiple errors during the start-up process, they will all flash in the
display. For example: if the fixtures has errors related to pan, tilt, and zoom all at the same
time, you will see the error message "PAN Er", "TILT Er", and "Zoom Er" flash and repeat 5
times.
If an error is detected during the initial start-up procedure, the fixture will self-generate a
second reset signal and try to realign all the motors and correct the errors. If the error per-
sists after a second attempt, a third attempt will be made. If after a third attempt all the
errors have not been corrected the fixture will make the following determinations:
• 3 or More Errors: The fixture cannot function properly with three or more errors, and
therefore the fixture will place itself in stand-by mode until subsequent repairs can be
made.
• Less Than 3 Errors: The fixture has less than 3 errors. Most other functions will work
properly. The fixture will attempt to operate normally until the errors can be corrected
by a technician. The errors in question will remain flashing in the display as a reminder of
internal errors.
ERROR CODE
PAN Er
TILT Er
Zoom Er
Error codes are subject to change without any prior written notice.
DESCRIPTION
Movement is not located in the default position after the reset. This
message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed, or magnet is missing) or there
is a motor failure (defective motor or a defective motor IC drive on
the main PCB). This error may also be displayed if the head/yoke was
blocked during TILT Er a reset function.
Movement is not located in the default position after the reset. This
message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed, or magnet is missing) or there is
a motor failure (defective motor or a defective motor IC drive on the
main PCB).