T O R Q U E S E T T I N G S F O R S C R E W S
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE
ISSUES! TO CONFIRM THE IP65 INTEGRITY AFTER A LAMP REPLACEMENT,
TEST THE FIXTURE USING THE IP TESTER. CONTACT ELATION SERVICE
FOR MORE DETAILS.
CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS
STRONGLY RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST!
AVOID PLACING YOUR FACE, EYES, HANDS, ETC IN CLOSE PROXIMITY TO
THE FIXTURE'S LENS WHILE PERFORMING THE TEST!
Test Type
Vacuum Test
Pressure Test
IP PRESSURE TESTING PARAMETERS
Minimum Pressure
-4.35 psi
(-30.00 KPa)
3.62 psi
(25.00 KPa)
Maximum Pressure
5.08 psi
(-35.00 KPa)
4.35 psi
(30.00 KPa)
21
Steady/Hold Time
10 sec
10 sec