L I G H T I N G C O N S O L E P AT C H I N G G U I D E L I N E S
There are also two additional parts for a primary control of the PROTEUS RAYZOR 1960,
which creates four separate control areas for the fixture. It is recommended to create fixture
groups on the lighting controller for each area of the fixture. (see below)
Main Fixture
RGBW Cells 1-19
Spark LED Main
Spark LEDs 1-76
SparkLED is not available as a mode in the fixture menu but must be provided as a console
control profile for easy programming of the fixture. Use the PROTEUS RAYZOR 1960 in
Extended mode and patch appropriate parts of the RGBW Pixels and SparkLED fixtures on
your control system to access all 176 channels.
On the lighting controller, patch the two fixture types (RGBW and SparkLED), separating the
SparkLEDs into a different ID range. (see below)
RGBW Pixels for Channels 1-98
SparkLEDs for Channels 99-176
ONYX
Main and Sub Fixture ID patch example below for a single PROTEUS RAYZOR 1960 fix-
ture.
Primary Pan, Tilt, RGBW Color, Strobe, Dimmer, Zoom, FX Controls
Red, Green, Blue, White per each individual cell
Primary Spark LED Strobe, Dimmer
Spark LED Dimmer per each individual LED
ID
1.0
RGBW Pixels Main
1.1
1.2
1.3
1.4
1.5
...
1.19
Pixel 19
1.20
Spark LED Main
101.1
Spark LED 1
101.2
Spark LED 2
101.3
Spark LED 3
101.4
Spark LED 4
...
101.76
Spark LED 76
TYPE
Pixel 1
Pixel 2
Pixel 3
Pixel 4
Pixel 5
...
...
32
ADDRESS
1
22
26
30
34
38
...
94
98
101
102
103
104
...
176