Error Codes - Elation PROTEUS RAYZOR 760 User Manual

Hide thumbs Also See for PROTEUS RAYZOR 760:
Table of Contents

Advertisement

E R R O R C O D E S
When power is applied, the unit will automatically enter a "Reset/Test" mode, which brings
all the internal motors to a home position. If there is an internal problem with one or more
of the motors, an error code will flash on the display screen. For example, when the display
shows "Pan Er" it means there is some type of error with the Pan motor. If there are multiple
errors during the start-up process they will all flash in the display. For example: if the fix-
tures has Pan, Tilt, and Zoom errors all at the same time, you will see the error message "Pan
Er", "Tilt Er", and "Zoom Er" flash in sequence 5 times.
If an error occurs during the initial start-up procedure, the fixture will self-generate a sec-
ond reset signal and try to realign all the motors and correct the errors. If the error persists
after a second attempt, a third attempt will be made. If after a third attempt all the errors
have not been corrected, the fixture will make the following determinations:
• 3 or More Errors - The fixture cannot function properly with three or more errors, and
therefore the fixture will place itself in stand-by mode until subsequent repairs can be
made.
• Less Than 3 Errors - The fixture has less than 3 errors, and therefore most other func-
tions will work properly. The fixture will attempt to operate normally until the errors can
be corrected by a technician. The errors in question will remain flashing in the display as a
reminder of internal errors.
Note: Error Codes are subject to change without any prior written notice.

ERROR CODES

Pan Er
Tilt Er
Zoom Er
DESCRIPTION
Movement is not located in the default position after the reset. This
message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed, or magnet is missing) or there
is a motor failure (defective motor or a defective motor IC drive on
the main PCB). This error may also be displayed if the head/yoke was
blocked during a reset function.
Movement is not located in the default position after the reset. This
message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed, or magnet is missing) or there is
a motor failure (defective motor or a defective motor IC drive on the
main PCB).