Example:
&%Z75,2
Sets the number of stop bits to 2.

75: Serial Out Parity

Purpose:
Selects the parity of a data stream sent from the
interface card to the printer. This setting becomes
active the next time the printer is turned on.
Syntax:
Z75,n
n =
0
None (default)
1
Odd
2
Even
Example:
&%Z75,2
Sets the outgoing parity to even.
98: Restore Factory Defaults, Print Self-Test, and Restore
Previously Defined Settings
Restores the factory default configuration selections,
Purpose:
prints the active configuration settings, or restores the
nonvolatile memory settings.
Syntax:
Z98,n
n =
0
Restores the factory setup
1
Prints the active configuration settings
2
Restores the settings stored in
nonvolatile memory
Example:
&%Z98,1
Prints the active configuration settings.
Notes:
To restore the settings in nonvolatile memory, place
&%Z98,2 at the end of the file.