Sending Commands To The Interface Card - Intermec EasyCoder 4630 User Manual

Coax/twinax interface card
Hide thumbs Also See for EasyCoder 4630:
Table of Contents

Advertisement

4630 and 4830 Coax/Twinax Interface Card User's Manual

Sending Commands to the Interface Card

You can download commands from the host to configure the interface
card and to access its advanced features. Host commands take effect
immediately and stay in active memory when the file or screen print is
received by the printer.
For example, to change the twinax address from 0 to 4, you would
send the following command:
&%Z00,4
where:
is the Command Pass-Thru delimiter.
&%
is the command identifier.
Z
is the command number.
00
is the separator between the command number and the
,
command setting.
is the command setting (address 4).
4
Multiple commands can be chained together using a slash (/) or
backslash (\) to separate the commands. For example, to set the
printer emulation ID to 4214 (Z24,3), save the setting (Z99,0), and then
print a test label (Z98,1), you would enter:
&%Z24,3\Z99,0\Z98,1
Note: If any part of the command syntax is incorrect, the interface ignores
the command and the printer prints from the point of the syntax error.