Features and Functions

Carrier Waveform

50
Soft Front Panel Operation
Click Mod
and then select AM
Figure 2-
15. To output the AM waveform, configure the
settings for the carrier frequency, modulating frequency,
depth, output amplitude, offset voltage, and the desired
waveform.

Figure 2-15 Panel view of AM

Remote Interface Operation
AM:STATe {0|OFF|1|ON}
The AM carrier waveform consists of Sine, Square, Ramp,
Triangle, or Arbitrary waveform. The default waveform is
Sine wave. You cannot use Pulse or DC as the carrier
waveform.
Soft Front Panel Operation
For Arbitrary waveform, select Arb
as shown in
Figure 2- 2
waveform from the drop down list
Figure 2-
16.
as shown in
at the top panel
and then select the desired